{"id":8132,"date":"2023-05-15T20:25:35","date_gmt":"2023-05-15T20:25:35","guid":{"rendered":"https:\/\/gasquip.com\/?p=8132"},"modified":"2023-06-20T13:24:09","modified_gmt":"2023-06-20T13:24:09","slug":"cuando-deberia-reemplazar-sus-mangueras-de-servicio-de-gas-sf6","status":"publish","type":"post","link":"https:\/\/gasquip.com\/es\/when-should-you-replace-your-sf6-gas-service-hoses\/","title":{"rendered":"\u00bfCu\u00e1ndo deber\u00eda reemplazar sus mangueras de servicio de gas SF6?"},"content":{"rendered":"<p><strong>Respuesta corta: <\/strong>al menos cada 6 a\u00f1os. <strong><a href=\"https:\/\/gasquip.com\/es\/categoria-producto\/sf6-gas-handling\/mangueras\/\">Haga clic aqu\u00ed para comprar<\/a><\/strong><\/p>\n\n\n\n<p><strong>Respuesta larga:<\/strong><\/p>\n\n\n\n<p>Siguiendo las pautas establecidas por DIN 20066 e ISO\/TR 17165-2, nuestro objetivo es garantizar la seguridad, el rendimiento y la longevidad de sus conjuntos de mangueras. Una manguera defectuosa provoca emisiones de gas SF6, contaminaci\u00f3n por gas, p\u00e9rdida de eficiencia y problemas de seguridad importantes. Al implementar las mejores pr\u00e1cticas para el almacenamiento y reemplazo de mangueras, puede optimizar la eficiencia y minimizar los riesgos. \u00a1Exploremos m\u00e1s!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Comprender el control de edad y la vida \u00fatil: <\/h2>\n\n\n\n<p>El control de la edad es crucial para garantizar que las mangueras de servicio de gas SF6 se utilicen antes de que expire su vida \u00fatil. La vida \u00fatil se refiere al per\u00edodo durante el cual la manguera conserva todas sus capacidades para el servicio previsto. El almacenamiento adecuado y el cumplimiento de las fechas de fabricaci\u00f3n son factores esenciales en el control de la edad y el uso de primero en entrar, primero en salir (FIFO).<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Directrices DIN 20066 e ISO\/TR 17165-2:<\/h2>\n\n\n\n<p>En los pa\u00edses de habla alemana, la norma DIN 20066:2002-10, a la que hacen referencia las asociaciones profesionales, ofrece recomendaciones espec\u00edficas para conjuntos de mangueras. De acuerdo a <a href=\"https:\/\/www.din.de\/en\"><strong>DIN 20066<\/strong><\/a>, la manguera de producci\u00f3n (manguera a granel) debe tener menos de 4 a\u00f1os a partir de la fecha de fabricaci\u00f3n. <strong>La vida \u00fatil total, incluido el almacenamiento, no debe exceder los 6 a\u00f1os.<\/strong> con un periodo de almacenamiento no superior a 2 de esos 6 a\u00f1os.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Inspecci\u00f3n visual y prueba de presi\u00f3n:<\/h2>\n\n\n\n<p>Independientemente del per\u00edodo de almacenamiento, es fundamental realizar una inspecci\u00f3n visual antes de utilizar mangueras almacenadas. Si surge alguna duda con respecto a la funcionalidad (p. ej., grietas, \u00f3xido u otros da\u00f1os), se deben realizar pruebas de presi\u00f3n antes de la implementaci\u00f3n. En los casos en los que persistan las dudas o existan da\u00f1os importantes, se recomienda desechar la manguera para garantizar la seguridad.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Mejores pr\u00e1cticas para el almacenamiento de mangueras:<\/h2>\n\n\n\n<p> El almacenamiento adecuado de la manguera es esencial para mantener la integridad y funcionalidad de la manguera. Estas son algunas de las mejores pr\u00e1cticas a seguir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ambiente limpio, fresco y seco: almacene las mangueras en un \u00e1rea limpia, fresca y seca, preferiblemente a temperatura ambiente, para evitar la degradaci\u00f3n.<\/li>\n\n\n\n<li>Protecci\u00f3n contra la luz solar y la humedad: Evite la exposici\u00f3n directa a la luz solar y la humedad, ya que pueden degradar el material de la manguera con el tiempo.<\/li>\n\n\n\n<li>Mant\u00e9ngase alejado de equipos el\u00e9ctricos de alta potencia: guarde las mangueras lejos de equipos el\u00e9ctricos de alta potencia para minimizar el riesgo de da\u00f1os el\u00e9ctricos.<\/li>\n\n\n\n<li>Evite productos qu\u00edmicos corrosivos: Evite el contacto entre las mangueras y productos qu\u00edmicos corrosivos, ya que pueden deteriorar los materiales de las mangueras.<\/li>\n\n\n\n<li>Protecci\u00f3n contra la luz ultravioleta: Proteja las mangueras de la exposici\u00f3n a la luz ultravioleta (UV), ya que puede acelerar la degradaci\u00f3n.<\/li>\n\n\n\n<li>Prot\u00e9jase contra insectos\/roedores: Tome precauciones para evitar infestaciones de insectos o roedores, que pueden causar da\u00f1os a las mangueras almacenadas.<\/li>\n\n\n\n<li>Separadas de materiales radiactivos: Almacene las mangueras separadas de materiales radiactivos para evitar cualquier posible contaminaci\u00f3n o interferencia.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">5. La seguridad es lo primero:<\/h2>\n\n\n\n<p>Considere siempre los conjuntos de mangueras como componentes relevantes para la seguridad. En caso de duda, priorice la seguridad realizando inspecciones exhaustivas, pruebas de presi\u00f3n o desechando mangueras que muestren signos de da\u00f1o o degradaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00bfEs hora de adquirir algunas mangueras SF6 nuevas? <\/h2>\n\n\n\n<p> Vendemos mangueras de caucho para manipulaci\u00f3n de gas SF6 directamente en nuestro sitio web. <strong><a href=\"https:\/\/gasquip.com\/es\/categoria-producto\/sf6-gas-handling\/mangueras\/\">haga clic aqu\u00ed<\/a><\/strong> para ver lo que ofrecemos. \u00bfTiene un proyecto personalizado o desea un ensamblaje, accesorio o material personalizado? <strong><a href=\"https:\/\/gasquip.com\/es\/categoria-producto\/sf6-gas-handling\/mangueras\/\">Comun\u00edquese con nosotros.<\/a><\/strong> <\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-1024x1024.png\" alt=\"Manguera de gas SF6 DN20\" class=\"wp-image-5321\" width=\"236\" height=\"236\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-300x300.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-150x150.png 150w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-768x768.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-600x600.png 600w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-100x100.png 100w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Short answer: at least every 6 years. Click here to buy Long answer: Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of your hose assemblies. A bad hose leads to SF6 gas emissions, gas contaminations, loss of efficiency, and major safety concerns. By [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5321,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[19,79,1],"tags":[],"class_list":["post-8132","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","category-learning","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>When Should You Replace Your SF6 Gas Service Hoses?<\/title>\n<meta name=\"description\" content=\"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gasquip.com\/es\/cuando-deberia-reemplazar-sus-mangueras-de-servicio-de-gas-sf6\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"When Should You Replace Your SF6 Gas Service Hoses?\" \/>\n<meta property=\"og:description\" content=\"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gasquip.com\/es\/cuando-deberia-reemplazar-sus-mangueras-de-servicio-de-gas-sf6\/\" \/>\n<meta property=\"og:site_name\" content=\"GasQuip\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/gasquiptx\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-15T20:25:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-20T13:24:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Luke Benden\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Luke Benden\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"},\"author\":{\"name\":\"Luke Benden\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\"},\"headline\":\"When Should You Replace Your SF6 Gas Service Hoses?\",\"datePublished\":\"2023-05-15T20:25:35+00:00\",\"dateModified\":\"2023-06-20T13:24:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"},\"wordCount\":495,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"articleSection\":[\"General\",\"Learning\",\"Uncategorized\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\",\"name\":\"When Should You Replace Your SF6 Gas Service Hoses?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"datePublished\":\"2023-05-15T20:25:35+00:00\",\"dateModified\":\"2023-06-20T13:24:09+00:00\",\"description\":\"Adhering to guidelines set forth by DIN 20066 and ISO\\\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"width\":1024,\"height\":1024,\"caption\":\"DN20 SF6 Gas Hose\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/gasquip.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"When Should You Replace Your SF6 Gas Service Hoses?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"name\":\"GasQuip\",\"description\":\"SF6 Gas Equipment\",\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/gasquip.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\",\"name\":\"GasQuip\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"width\":2819,\"height\":702,\"caption\":\"GasQuip\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/gasquiptx\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/gasquip.com\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCUCicTtyc2zeJMcj5NMA0Ww\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\",\"name\":\"Luke Benden\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"caption\":\"Luke Benden\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00bfCu\u00e1ndo deber\u00eda reemplazar sus mangueras de servicio de gas SF6?","description":"Siguiendo las pautas establecidas por DIN 20066 e ISO\/TR 17165-2, nuestro objetivo es garantizar la seguridad, el rendimiento y la longevidad de las mangueras.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gasquip.com\/es\/cuando-deberia-reemplazar-sus-mangueras-de-servicio-de-gas-sf6\/","og_locale":"es_MX","og_type":"article","og_title":"When Should You Replace Your SF6 Gas Service Hoses?","og_description":"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.","og_url":"https:\/\/gasquip.com\/es\/cuando-deberia-reemplazar-sus-mangueras-de-servicio-de-gas-sf6\/","og_site_name":"GasQuip","article_publisher":"https:\/\/www.facebook.com\/gasquiptx","article_published_time":"2023-05-15T20:25:35+00:00","article_modified_time":"2023-06-20T13:24:09+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","type":"image\/png"}],"author":"Luke Benden","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Luke Benden","Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#article","isPartOf":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"},"author":{"name":"Luke Benden","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf"},"headline":"When Should You Replace Your SF6 Gas Service Hoses?","datePublished":"2023-05-15T20:25:35+00:00","dateModified":"2023-06-20T13:24:09+00:00","mainEntityOfPage":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"},"wordCount":495,"commentCount":0,"publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"image":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","articleSection":["General","Learning","Uncategorized"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/","url":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/","name":"\u00bfCu\u00e1ndo deber\u00eda reemplazar sus mangueras de servicio de gas SF6?","isPartOf":{"@id":"https:\/\/gasquip.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"image":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","datePublished":"2023-05-15T20:25:35+00:00","dateModified":"2023-06-20T13:24:09+00:00","description":"Siguiendo las pautas establecidas por DIN 20066 e ISO\/TR 17165-2, nuestro objetivo es garantizar la seguridad, el rendimiento y la longevidad de las mangueras.","breadcrumb":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","width":1024,"height":1024,"caption":"DN20 SF6 Gas Hose"},{"@type":"BreadcrumbList","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/gasquip.com\/"},{"@type":"ListItem","position":2,"name":"When Should You Replace Your SF6 Gas Service Hoses?"}]},{"@type":"WebSite","@id":"https:\/\/gasquip.com\/#website","url":"https:\/\/gasquip.com\/","name":"GasQuip","description":"Equipos de gas SF6","publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gasquip.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/gasquip.com\/#organization","name":"GasQuip","url":"https:\/\/gasquip.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","width":2819,"height":702,"caption":"GasQuip"},"image":{"@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/gasquiptx","https:\/\/www.linkedin.com\/company\/gasquip.com","https:\/\/www.youtube.com\/channel\/UCUCicTtyc2zeJMcj5NMA0Ww"]},{"@type":"Person","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf","name":"Lucas Benden","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","caption":"Luke Benden"}}]}},"_links":{"self":[{"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/posts\/8132","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/comments?post=8132"}],"version-history":[{"count":0,"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/posts\/8132\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/media\/5321"}],"wp:attachment":[{"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/media?parent=8132"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/categories?post=8132"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gasquip.com\/es\/wp-json\/wp\/v2\/tags?post=8132"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}