{"id":8132,"date":"2023-05-15T20:25:35","date_gmt":"2023-05-15T20:25:35","guid":{"rendered":"https:\/\/gasquip.com\/?p=8132"},"modified":"2023-06-20T13:24:09","modified_gmt":"2023-06-20T13:24:09","slug":"quand-devriez-vous-remplacer-vos-tuyaux-de-service-de-gaz-sf6","status":"publish","type":"post","link":"https:\/\/gasquip.com\/fr\/when-should-you-replace-your-sf6-gas-service-hoses\/","title":{"rendered":"Quand devriez-vous remplacer vos tuyaux de service de gaz SF6\u00a0?"},"content":{"rendered":"<p><strong>R\u00e9ponse courte: <\/strong>au moins tous les 6 ans. <strong><a href=\"https:\/\/gasquip.com\/fr\/categorie-de-produit\/sf6-gas-handling\/tuyaux\/\">Cliquez ici pour acheter<\/a><\/strong><\/p>\n\n\n\n<p><strong>Longue r\u00e9ponse:<\/strong><\/p>\n\n\n\n<p>Adh\u00e9rant aux directives \u00e9tablies par les normes DIN 20066 et ISO\/TR 17165-2, nous visons \u00e0 garantir la s\u00e9curit\u00e9, les performances et la long\u00e9vit\u00e9 de vos flexibles. Un mauvais tuyau entra\u00eene des \u00e9missions de gaz SF6, des contaminations par gaz, une perte d&#039;efficacit\u00e9 et des probl\u00e8mes de s\u00e9curit\u00e9 majeurs. En mettant en \u0153uvre les meilleures pratiques pour le stockage et le remplacement des tuyaux, vous pouvez optimiser l&#039;efficacit\u00e9 tout en minimisant les risques. Explorons plus loin\u00a0!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Comprendre le contr\u00f4le de l\u2019\u00e2ge et la dur\u00e9e de conservation\u00a0: <\/h2>\n\n\n\n<p>Le contr\u00f4le de l&#039;\u00e2ge est crucial pour garantir que les tuyaux de service de gaz SF6 sont utilis\u00e9s avant l&#039;expiration de leur dur\u00e9e de conservation. La dur\u00e9e de conservation fait r\u00e9f\u00e9rence \u00e0 la p\u00e9riode pendant laquelle le tuyau conserve toutes ses capacit\u00e9s pour le service pr\u00e9vu. Un stockage appropri\u00e9 et le respect des dates de fabrication sont des facteurs essentiels dans le contr\u00f4le de l\u2019\u00e2ge et l\u2019utilisation du premier entr\u00e9, premier sorti (FIFO).<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Directives DIN 20066 et ISO\/TR 17165-2\u00a0:<\/h2>\n\n\n\n<p>Dans les pays germanophones, la norme DIN 20066:2002-10, invoqu\u00e9e par les associations professionnelles, fournit des recommandations sp\u00e9cifiques pour les flexibles. Selon <a href=\"https:\/\/www.din.de\/en\"><strong>DIN 20066<\/strong><\/a>, le tuyau de production (tuyau en vrac) doit \u00eatre \u00e2g\u00e9 de moins de 4 ans \u00e0 compter de la date de fabrication. <strong>La dur\u00e9e de vie globale, stockage compris, ne doit pas d\u00e9passer 6 ans,<\/strong> avec une dur\u00e9e de stockage n&#039;exc\u00e9dant pas 2 de ces 6 ans.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Inspection visuelle et tests de pression\u00a0:<\/h2>\n\n\n\n<p>Quelle que soit la dur\u00e9e de stockage, il est crucial de proc\u00e9der \u00e0 une inspection visuelle avant d\u2019utiliser les tuyaux stock\u00e9s. En cas de doute concernant la fonctionnalit\u00e9 (par exemple, fissures, rouille ou autres dommages), des tests de pression doivent \u00eatre effectu\u00e9s avant le d\u00e9ploiement. Dans les cas o\u00f9 des doutes persistent ou si des dommages importants sont pr\u00e9sents, il est recommand\u00e9 de jeter le tuyau pour garantir la s\u00e9curit\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Meilleures pratiques pour le stockage des tuyaux\u00a0:<\/h2>\n\n\n\n<p> Un stockage appropri\u00e9 des tuyaux est essentiel pour maintenir leur int\u00e9grit\u00e9 et leur fonctionnalit\u00e9. Voici quelques bonnes pratiques \u00e0 suivre\u00a0:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Environnement propre, frais et sec\u00a0: stockez les tuyaux dans un endroit propre, frais et sec, de pr\u00e9f\u00e9rence \u00e0 temp\u00e9rature ambiante, pour \u00e9viter toute d\u00e9gradation.<\/li>\n\n\n\n<li>Protection contre la lumi\u00e8re du soleil et l&#039;humidit\u00e9\u00a0: \u00e9vitez l&#039;exposition directe \u00e0 la lumi\u00e8re du soleil et \u00e0 l&#039;humidit\u00e9, car elles peuvent d\u00e9grader le mat\u00e9riau du tuyau au fil du temps.<\/li>\n\n\n\n<li>Tenir \u00e0 l&#039;\u00e9cart des \u00e9quipements \u00e9lectriques \u00e0 haute puissance\u00a0: rangez les tuyaux \u00e0 l&#039;\u00e9cart des \u00e9quipements \u00e9lectriques \u00e0 haute puissance afin de minimiser le risque de dommages \u00e9lectriques.<\/li>\n\n\n\n<li>\u00c9vitez les produits chimiques corrosifs\u00a0: \u00e9vitez tout contact entre les tuyaux et les produits chimiques corrosifs, car ils peuvent d\u00e9t\u00e9riorer les mat\u00e9riaux des tuyaux.<\/li>\n\n\n\n<li>Protection contre la lumi\u00e8re ultraviolette\u00a0: Prot\u00e9gez les tuyaux de l&#039;exposition \u00e0 la lumi\u00e8re ultraviolette (UV), car elle peut acc\u00e9l\u00e9rer la d\u00e9gradation.<\/li>\n\n\n\n<li>Protection contre les insectes\/rongeurs\u00a0: Prenez des pr\u00e9cautions pour \u00e9viter les infestations d&#039;insectes ou de rongeurs, qui peuvent endommager les tuyaux stock\u00e9s.<\/li>\n\n\n\n<li>S\u00e9par\u00e9 des mati\u00e8res radioactives\u00a0: stocker les tuyaux s\u00e9par\u00e9ment des mati\u00e8res radioactives pour \u00e9viter toute contamination ou interf\u00e9rence potentielle.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">5. La s\u00e9curit\u00e9 avant tout\u00a0:<\/h2>\n\n\n\n<p>Consid\u00e9rez toujours les flexibles comme des composants importants pour la s\u00e9curit\u00e9. En cas de doute, donnez la priorit\u00e9 \u00e0 la s\u00e9curit\u00e9 en effectuant des inspections approfondies, des tests de pression ou en \u00e9liminant les tuyaux qui pr\u00e9sentent des signes de dommages ou de d\u00e9gradation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Il est temps d&#039;acheter de nouveaux tuyaux SF6\u00a0? <\/h2>\n\n\n\n<p> Nous vendons des tuyaux en caoutchouc pour la manipulation du gaz SF6 directement sur notre site Internet. <strong><a href=\"https:\/\/gasquip.com\/fr\/categorie-de-produit\/sf6-gas-handling\/tuyaux\/\">Cliquez ici<\/a><\/strong> pour d\u00e9couvrir ce que nous proposons. Vous avez un projet personnalis\u00e9 ou souhaitez un assemblage, un raccord ou un mat\u00e9riau personnalis\u00e9\u00a0? <strong><a href=\"https:\/\/gasquip.com\/fr\/categorie-de-produit\/sf6-gas-handling\/tuyaux\/\">Contactez-nous.<\/a><\/strong> <\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-1024x1024.png\" alt=\"Tuyau de gaz DN20 SF6\" class=\"wp-image-5321\" width=\"236\" height=\"236\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-300x300.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-150x150.png 150w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-768x768.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-600x600.png 600w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-100x100.png 100w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Short answer: at least every 6 years. Click here to buy Long answer: Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of your hose assemblies. A bad hose leads to SF6 gas emissions, gas contaminations, loss of efficiency, and major safety concerns. By [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5321,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[19,79,1],"tags":[],"class_list":["post-8132","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","category-learning","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>When Should You Replace Your SF6 Gas Service Hoses?<\/title>\n<meta name=\"description\" content=\"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gasquip.com\/fr\/quand-devriez-vous-remplacer-vos-tuyaux-de-service-de-gaz-sf6\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"When Should You Replace Your SF6 Gas Service Hoses?\" \/>\n<meta property=\"og:description\" content=\"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gasquip.com\/fr\/quand-devriez-vous-remplacer-vos-tuyaux-de-service-de-gaz-sf6\/\" \/>\n<meta property=\"og:site_name\" content=\"GasQuip\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/gasquiptx\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-15T20:25:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-20T13:24:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Luke Benden\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Luke Benden\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"},\"author\":{\"name\":\"Luke Benden\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\"},\"headline\":\"When Should You Replace Your SF6 Gas Service Hoses?\",\"datePublished\":\"2023-05-15T20:25:35+00:00\",\"dateModified\":\"2023-06-20T13:24:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"},\"wordCount\":495,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"articleSection\":[\"General\",\"Learning\",\"Uncategorized\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\",\"name\":\"When Should You Replace Your SF6 Gas Service Hoses?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"datePublished\":\"2023-05-15T20:25:35+00:00\",\"dateModified\":\"2023-06-20T13:24:09+00:00\",\"description\":\"Adhering to guidelines set forth by DIN 20066 and ISO\\\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"width\":1024,\"height\":1024,\"caption\":\"DN20 SF6 Gas Hose\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/gasquip.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"When Should You Replace Your SF6 Gas Service Hoses?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"name\":\"GasQuip\",\"description\":\"SF6 Gas Equipment\",\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/gasquip.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\",\"name\":\"GasQuip\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"width\":2819,\"height\":702,\"caption\":\"GasQuip\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/gasquiptx\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/gasquip.com\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCUCicTtyc2zeJMcj5NMA0Ww\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\",\"name\":\"Luke Benden\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"caption\":\"Luke Benden\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Quand devriez-vous remplacer vos tuyaux de service de gaz SF6\u00a0?","description":"Adh\u00e9rant aux directives \u00e9tablies par les normes DIN 20066 et ISO\/TR 17165-2, nous visons \u00e0 garantir la s\u00e9curit\u00e9, les performances et la long\u00e9vit\u00e9 des tuyaux.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gasquip.com\/fr\/quand-devriez-vous-remplacer-vos-tuyaux-de-service-de-gaz-sf6\/","og_locale":"fr_FR","og_type":"article","og_title":"When Should You Replace Your SF6 Gas Service Hoses?","og_description":"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.","og_url":"https:\/\/gasquip.com\/fr\/quand-devriez-vous-remplacer-vos-tuyaux-de-service-de-gaz-sf6\/","og_site_name":"GasQuip","article_publisher":"https:\/\/www.facebook.com\/gasquiptx","article_published_time":"2023-05-15T20:25:35+00:00","article_modified_time":"2023-06-20T13:24:09+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","type":"image\/png"}],"author":"Luke Benden","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Luke Benden","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#article","isPartOf":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"},"author":{"name":"Luke Benden","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf"},"headline":"When Should You Replace Your SF6 Gas Service Hoses?","datePublished":"2023-05-15T20:25:35+00:00","dateModified":"2023-06-20T13:24:09+00:00","mainEntityOfPage":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"},"wordCount":495,"commentCount":0,"publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"image":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","articleSection":["General","Learning","Uncategorized"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/","url":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/","name":"Quand devriez-vous remplacer vos tuyaux de service de gaz SF6\u00a0?","isPartOf":{"@id":"https:\/\/gasquip.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"image":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","datePublished":"2023-05-15T20:25:35+00:00","dateModified":"2023-06-20T13:24:09+00:00","description":"Adh\u00e9rant aux directives \u00e9tablies par les normes DIN 20066 et ISO\/TR 17165-2, nous visons \u00e0 garantir la s\u00e9curit\u00e9, les performances et la long\u00e9vit\u00e9 des tuyaux.","breadcrumb":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","width":1024,"height":1024,"caption":"DN20 SF6 Gas Hose"},{"@type":"BreadcrumbList","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/gasquip.com\/"},{"@type":"ListItem","position":2,"name":"When Should You Replace Your SF6 Gas Service Hoses?"}]},{"@type":"WebSite","@id":"https:\/\/gasquip.com\/#website","url":"https:\/\/gasquip.com\/","name":"GazQuip","description":"\u00c9quipement de gaz SF6","publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gasquip.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/gasquip.com\/#organization","name":"GazQuip","url":"https:\/\/gasquip.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","width":2819,"height":702,"caption":"GasQuip"},"image":{"@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/gasquiptx","https:\/\/www.linkedin.com\/company\/gasquip.com","https:\/\/www.youtube.com\/channel\/UCUCicTtyc2zeJMcj5NMA0Ww"]},{"@type":"Person","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf","name":"Luc Benden","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","caption":"Luke Benden"}}]}},"_links":{"self":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/posts\/8132","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/comments?post=8132"}],"version-history":[{"count":0,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/posts\/8132\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/media\/5321"}],"wp:attachment":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/media?parent=8132"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/categories?post=8132"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/tags?post=8132"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}