{"id":9148,"date":"2024-02-20T21:02:29","date_gmt":"2024-02-20T21:02:29","guid":{"rendered":"https:\/\/gasquip.com\/?p=9148"},"modified":"2024-02-20T21:42:22","modified_gmt":"2024-02-20T21:42:22","slug":"surmonter-5-problemes-majeurs-avec-les-analyseurs-de-gaz-sf6","status":"publish","type":"post","link":"https:\/\/gasquip.com\/fr\/overcoming-5-major-problems-with-sf6-gas-analyzers\/","title":{"rendered":"Surmonter 5 probl\u00e8mes majeurs avec les analyseurs de gaz SF6"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong>Probl\u00e8me 1\u00a0:\u00a0temps d&#039;attente pour l&#039;\u00e9talonnage<\/strong><\/h2>\n\n\n\n<p>Avant de commencer le d\u00e9veloppement du FLEX, le retour le plus important que nous recevions des clients concernant les analyseurs SF6 \u00e9tait de devoir les renvoyer au fabricant pour \u00e9talonnage. En th\u00e9orie, c&#039;est un processus simple et vous r\u00e9cup\u00e9rez votre appareil enti\u00e8rement calibr\u00e9 en quelques semaines. En pratique, c\u2019\u00e9tait toujours une autre histoire. Les probl\u00e8mes incluent la n\u00e9cessit\u00e9 de coordonner le retour, des co\u00fbts inattendus ou des prix abusifs, des mois d&#039;attente pour r\u00e9cup\u00e9rer l&#039;\u00e9quipement ou l&#039;\u00e9quipement endommag\u00e9 pendant le transport vers ou depuis le laboratoire d&#039;\u00e9talonnage. Cela cr\u00e9e une exp\u00e9rience tr\u00e8s d\u00e9sagr\u00e9able tant pour le fabricant que pour le client.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Solution\u00a0: modules de capteurs<\/strong><\/h3>\n\n\n\n<p>Le FLEX a \u00e9t\u00e9 con\u00e7u autour d&#039;un collecteur de modules de capteurs 3 \u00d7 3 dans lequel sont log\u00e9s les capteurs de chaque type de gaz. Peu importe l&#039;emplacement auquel chaque capteur est branch\u00e9, et il faut moins d&#039;une minute pour remplacer un nouveau capteur pr\u00e9-calibr\u00e9. Nous fournissons m\u00eame la cl\u00e9 dynamom\u00e9trique pour que l&#039;installation soit la plus s\u00fbre possible. D\u00e9sormais, au lieu de nous renvoyer le FLEX, nous vous enverrons des modules de capteurs pr\u00e9calibr\u00e9s et pr\u00eats \u00e0 l&#039;emploi. Non seulement cela, mais si vous d\u00e9cidez d&#039;ajouter un autre type de capteur de gaz, ou si une nouvelle norme arrive dans des ann\u00e9es et n\u00e9cessite la mesure d&#039;un nouveau contaminant ou d&#039;un nouveau gaz isolant, il vous suffit d&#039;ins\u00e9rer un nouveau module pour mettre \u00e0 niveau. .<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"794\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-1024x794.png\" alt=\"\" class=\"wp-image-9074\" style=\"width:284px;height:auto\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-1024x794.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-300x233.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-768x595.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-1536x1191.png 1536w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-15x12.png 15w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1-600x465.png 600w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/Calibration-Procedure-1.png 1580w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Probl\u00e8me 2\u00a0:\u00a0piles<\/strong><\/h2>\n\n\n\n<p>Un autre probl\u00e8me rencontr\u00e9 par les clients avec les analyseurs SF6 concerne les batteries. Encore une fois, en th\u00e9orie, ils fonctionneraient toujours, tiendraient les charges et seraient parfaits pour un appareil portable. En r\u00e9alit\u00e9, les clients ont signal\u00e9 avoir des probl\u00e8mes avec les batteries qui ne retenaient pas la charge, s&#039;usaient avec le temps, causaient des probl\u00e8mes d&#039;exp\u00e9dition en raison de la classification des marchandises dangereuses et les tests \u00e9taient affect\u00e9s lorsque la batterie \u00e9tait faible.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"590\" height=\"361\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Samsung-Galaxy-Note-4-Battery-Drain-Issue.jpg\" alt=\"\" class=\"wp-image-9152\" style=\"width:222px;height:auto\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Samsung-Galaxy-Note-4-Battery-Drain-Issue.jpg 590w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Samsung-Galaxy-Note-4-Battery-Drain-Issue-300x184.jpg 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Samsung-Galaxy-Note-4-Battery-Drain-Issue-18x12.jpg 18w\" sizes=\"(max-width: 590px) 100vw, 590px\" \/><\/figure>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Solution<\/strong>: <strong>Retirer la batterie<\/strong><\/h3>\n\n\n\n<p>Pour le FLEX, nous avons r\u00e9alis\u00e9 que la grande majorit\u00e9 de nos clients testaient des \u00e9quipements isol\u00e9s au SF6 \u00e0 l&#039;int\u00e9rieur de sous-stations, dans lesquelles il y a de nombreuses prises pour brancher des appareils. Et 9 fois sur 10, ils ont \u00e9galement des adaptateurs dans leurs camions pour brancher des appareils. Nous avons donc choisi de supprimer le poids suppl\u00e9mentaire et d\u2019\u00e9viter les maux de t\u00eate li\u00e9s \u00e0 la pr\u00e9sence d\u2019une batterie embarqu\u00e9e.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Probl\u00e8me 3\u00a0:\u00a0les tests d&#039;humidit\u00e9 indiquent des r\u00e9sultats plus \u00e9lev\u00e9s que pr\u00e9vu<\/strong><\/h2>\n\n\n\n<p>Si vous avez d\u00e9j\u00e0 utilis\u00e9 un analyseur SF6, vous savez probablement qu&#039;il faut parfois jusqu&#039;\u00e0 2 \u00e0 3 tests avant de pouvoir faire confiance aux r\u00e9sultats. La raison en est qu\u2019il y a de l\u2019humidit\u00e9 r\u00e9siduelle qui a tendance \u00e0 s\u2019infiltrer dans la plomberie des analyseurs lorsqu\u2019ils sont pos\u00e9s sur l\u2019\u00e9tag\u00e8re. L&#039;humidit\u00e9 peut p\u00e9n\u00e9trer par les tuyaux mouill\u00e9s, les r\u00e9gulateurs, les raccords ou tout autre objet ayant \u00e9t\u00e9 en contact avec l&#039;air ambiant ou les mains moites. Apr\u00e8s quelques tests, suffisamment de gaz a travers\u00e9 le syst\u00e8me pour \u00e9liminer une partie de cette humidit\u00e9 r\u00e9siduelle et \u00ab s\u00e9cher \u00bb efficacement le syst\u00e8me. La zone qui affecte le plus la lecture des capteurs est \u00e9videmment l&#039;endroit o\u00f9 le capteur est mont\u00e9, qui a tendance \u00e0 \u00eatre une zone \u00ab morte \u00bb o\u00f9 l&#039;humidit\u00e9 peut s&#039;accumuler. Le probl\u00e8me est que vous ne savez jamais si le syst\u00e8me est compl\u00e8tement sec et que vous perdez du temps et de l\u2019essence pour obtenir un syst\u00e8me sec.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Solution\u00a0:\u00a0s\u00e9chage du capteur et du syst\u00e8me chauff\u00e9s<\/strong><\/h3>\n\n\n\n<p>Le FLEX dispose d&#039;une fonction int\u00e9gr\u00e9e appel\u00e9e \u00ab Dry System \u00bb qui fait le vide sur tous les composants internes et modules de capteurs pour aider \u00e0 \u00e9liminer cette humidit\u00e9. De plus, nous utilisons un capteur polym\u00e8re capacitif avanc\u00e9 \u00e0 l&#039;int\u00e9rieur de notre module H2O dot\u00e9 d&#039;un chauffage int\u00e9gr\u00e9. Ce chauffage fonctionne pendant le s\u00e9chage du syst\u00e8me et avant les tests d&#039;\u00e9chantillons, ce qui aide \u00e9galement \u00e0 \u00e9liminer l&#039;humidit\u00e9 r\u00e9siduelle dans le syst\u00e8me.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View.png\" alt=\"\" class=\"wp-image-9153\" style=\"width:274px;height:auto\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View-300x300.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View-150x150.png 150w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View-768x768.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View-12x12.png 12w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View-600x600.png 600w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/FLEX-H20-Sensor-Module-No-BG-Exp-View-100x100.png 100w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Probl\u00e8me 4\u00a0:\u00a0Exploiter des appareils en plein soleil<\/strong><\/h2>\n\n\n\n<p>C&#039;est une \u00e9vidence, mais les clients nous ont plaints de ne pas pouvoir voir les \u00e9crans de leurs analyseurs SF6 (et autres \u00e9quipements de test de puissance) en plein soleil.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image.png\" alt=\"\" class=\"wp-image-9154\" style=\"width:179px;height:auto\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image-300x300.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image-150x150.png 150w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image-768x768.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image-12x12.png 12w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image-600x600.png 600w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/image-100x100.png 100w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Solution\u00a0: affichage lisible \u00e0 la lumi\u00e8re du soleil et palette de couleurs \u00e0 contraste \u00e9lev\u00e9<\/strong><\/h3>\n\n\n\n<p>Le 7 pouces du FLEX utilise un \u00e9cran lisible en plein soleil et une palette de couleurs d&#039;interface sp\u00e9cialement con\u00e7ue pour faciliter la lecture au soleil. C&#039;est vraiment une de ces choses qu&#039;il faut voir par soi-m\u00eame.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"600\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/ms_sample_fail_sf6.png\" alt=\"\" class=\"wp-image-9155\" style=\"width:333px;height:auto\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/ms_sample_fail_sf6.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/ms_sample_fail_sf6-300x176.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/ms_sample_fail_sf6-768x450.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/ms_sample_fail_sf6-18x12.png 18w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/ms_sample_fail_sf6-600x352.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:45px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Probl\u00e8me 5\u00a0:<\/strong> <strong>Acc\u00e8s et entretien des sacs<\/strong><\/h2>\n\n\n\n<p>La derni\u00e8re plainte majeure que nous avons entendue de la part des clients concernait le manque de possibilit\u00e9 d&#039;acc\u00e9der au sac de stockage de gaz interne pour la maintenance. Ce qui est ironique, c&#039;est que la raison pour laquelle les clients voulaient acc\u00e9der au sac est qu&#039;ils \u00e9chouaient constamment sur le terrain. La plupart des sacs d&#039;analyseurs utilisent un sac en plastique de style poly qui est id\u00e9al pour ne pas emprisonner l&#039;humidit\u00e9, mais terrible pour ne pas se fissurer par temps froid et ne pas fuir avec le temps. Pensez \u00e0 un sac Ziploc surdimensionn\u00e9 auquel est attach\u00e9 un raccord en plastique, pas vraiment robuste.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Solution\u00a0: panneau d&#039;acc\u00e8s aux sacs et meilleurs mat\u00e9riaux<\/strong><\/h3>\n\n\n\n<p>Le FLEX dispose d&#039;un panneau d&#039;acc\u00e8s au sac int\u00e9gr\u00e9 sur le dessus de l&#039;appareil. Si vous retirez les 4 vis maintenant le panneau, vous d\u00e9couvrirez un sac en PVC renforc\u00e9 avec un raccord m\u00e9tallique qui PEUT r\u00e9sister \u00e0 la pressurisation et \u00e0 la d\u00e9pressurisation constantes qu&#039;un analyseur peut supporter. Retirer le sac est aussi simple que de d\u00e9connecter un \u00e9crou et de retirer le sac.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Untitled-design-8.png\" alt=\"\" class=\"wp-image-9156\" style=\"width:304px;height:auto\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Untitled-design-8.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Untitled-design-8-300x168.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Untitled-design-8-768x429.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Untitled-design-8-18x10.png 18w, https:\/\/gasquip.com\/wp-content\/uploads\/2024\/02\/Untitled-design-8-600x335.png 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:44px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Vous n&#039;avez pas encore vu le FLEX ? V\u00e9rifiez-le <strong><a href=\"https:\/\/gasquip.com\/fr\/produit\/analyseur-flexible-sf6\/\">ICI<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Problem 1: Calibration Wait Times Prior to starting development on the FLEX, the feedback we got most from customers about SF6 analyzers was having to send them back to the manufacturer for calibration. In theory, it\u2019s an easy process and you get your device back fully calibrated in a few weeks. In practice, it was [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8836,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[19,79],"tags":[],"class_list":["post-9148","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","category-learning"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Overcoming 5 Major Problems with SF6 Gas Analyzers<\/title>\n<meta name=\"description\" content=\"Prior to developing FLEX, we spoke to customers about the 5 biggest problems they had with their current devices.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gasquip.com\/fr\/surmonter-5-problemes-majeurs-avec-les-analyseurs-de-gaz-sf6\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Overcoming 5 Major Problems with SF6 Gas Analyzers\" \/>\n<meta property=\"og:description\" content=\"Prior to developing FLEX, we spoke to customers about the 5 biggest problems they had with their current devices.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gasquip.com\/fr\/surmonter-5-problemes-majeurs-avec-les-analyseurs-de-gaz-sf6\/\" \/>\n<meta property=\"og:site_name\" content=\"GasQuip\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/gasquiptx\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-20T21:02:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-20T21:42:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/IMG_2230-e1702587763236.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1536\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Luke Benden\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Luke Benden\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/\"},\"author\":{\"name\":\"Luke Benden\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\"},\"headline\":\"Overcoming 5 Major Problems with SF6 Gas Analyzers\",\"datePublished\":\"2024-02-20T21:02:29+00:00\",\"dateModified\":\"2024-02-20T21:42:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/\"},\"wordCount\":859,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/IMG_2230-e1702587763236.jpeg\",\"articleSection\":[\"General\",\"Learning\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/\",\"name\":\"Overcoming 5 Major Problems with SF6 Gas Analyzers\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/IMG_2230-e1702587763236.jpeg\",\"datePublished\":\"2024-02-20T21:02:29+00:00\",\"dateModified\":\"2024-02-20T21:42:22+00:00\",\"description\":\"Prior to developing FLEX, we spoke to customers about the 5 biggest problems they had with their current devices.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/IMG_2230-e1702587763236.jpeg\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/09\\\/IMG_2230-e1702587763236.jpeg\",\"width\":1536,\"height\":1536},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/overcoming-5-major-problems-with-sf6-gas-analyzers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/gasquip.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Overcoming 5 Major Problems with SF6 Gas Analyzers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"name\":\"GasQuip\",\"description\":\"SF6 Gas Equipment\",\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/gasquip.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\",\"name\":\"GasQuip\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"width\":2819,\"height\":702,\"caption\":\"GasQuip\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/gasquiptx\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/gasquip.com\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCUCicTtyc2zeJMcj5NMA0Ww\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\",\"name\":\"Luke Benden\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"caption\":\"Luke Benden\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Surmonter 5 probl\u00e8mes majeurs avec les analyseurs de gaz SF6","description":"Avant de d\u00e9velopper FLEX, nous avons discut\u00e9 avec nos clients des cinq plus gros probl\u00e8mes qu&#039;ils rencontraient avec leurs appareils actuels.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gasquip.com\/fr\/surmonter-5-problemes-majeurs-avec-les-analyseurs-de-gaz-sf6\/","og_locale":"fr_FR","og_type":"article","og_title":"Overcoming 5 Major Problems with SF6 Gas Analyzers","og_description":"Prior to developing FLEX, we spoke to customers about the 5 biggest problems they had with their current devices.","og_url":"https:\/\/gasquip.com\/fr\/surmonter-5-problemes-majeurs-avec-les-analyseurs-de-gaz-sf6\/","og_site_name":"GasQuip","article_publisher":"https:\/\/www.facebook.com\/gasquiptx","article_published_time":"2024-02-20T21:02:29+00:00","article_modified_time":"2024-02-20T21:42:22+00:00","og_image":[{"width":1536,"height":1536,"url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/IMG_2230-e1702587763236.jpeg","type":"image\/jpeg"}],"author":"Luke Benden","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Luke Benden","Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#article","isPartOf":{"@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/"},"author":{"name":"Luke Benden","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf"},"headline":"Overcoming 5 Major Problems with SF6 Gas Analyzers","datePublished":"2024-02-20T21:02:29+00:00","dateModified":"2024-02-20T21:42:22+00:00","mainEntityOfPage":{"@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/"},"wordCount":859,"commentCount":0,"publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"image":{"@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/IMG_2230-e1702587763236.jpeg","articleSection":["General","Learning"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/","url":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/","name":"Surmonter 5 probl\u00e8mes majeurs avec les analyseurs de gaz SF6","isPartOf":{"@id":"https:\/\/gasquip.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#primaryimage"},"image":{"@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/IMG_2230-e1702587763236.jpeg","datePublished":"2024-02-20T21:02:29+00:00","dateModified":"2024-02-20T21:42:22+00:00","description":"Avant de d\u00e9velopper FLEX, nous avons discut\u00e9 avec nos clients des cinq plus gros probl\u00e8mes qu&#039;ils rencontraient avec leurs appareils actuels.","breadcrumb":{"@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#primaryimage","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/IMG_2230-e1702587763236.jpeg","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/09\/IMG_2230-e1702587763236.jpeg","width":1536,"height":1536},{"@type":"BreadcrumbList","@id":"https:\/\/gasquip.com\/overcoming-5-major-problems-with-sf6-gas-analyzers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/gasquip.com\/"},{"@type":"ListItem","position":2,"name":"Overcoming 5 Major Problems with SF6 Gas Analyzers"}]},{"@type":"WebSite","@id":"https:\/\/gasquip.com\/#website","url":"https:\/\/gasquip.com\/","name":"GazQuip","description":"\u00c9quipement de gaz SF6","publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gasquip.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/gasquip.com\/#organization","name":"GazQuip","url":"https:\/\/gasquip.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","width":2819,"height":702,"caption":"GasQuip"},"image":{"@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/gasquiptx","https:\/\/www.linkedin.com\/company\/gasquip.com","https:\/\/www.youtube.com\/channel\/UCUCicTtyc2zeJMcj5NMA0Ww"]},{"@type":"Person","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf","name":"Luc Benden","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","caption":"Luke Benden"}}]}},"_links":{"self":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/posts\/9148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/comments?post=9148"}],"version-history":[{"count":0,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/posts\/9148\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/media\/8836"}],"wp:attachment":[{"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/media?parent=9148"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/categories?post=9148"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gasquip.com\/fr\/wp-json\/wp\/v2\/tags?post=9148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}