{"id":8132,"date":"2023-05-15T20:25:35","date_gmt":"2023-05-15T20:25:35","guid":{"rendered":"https:\/\/gasquip.com\/?p=8132"},"modified":"2023-06-20T13:24:09","modified_gmt":"2023-06-20T13:24:09","slug":"quando-voce-deve-substituir-suas-mangueiras-de-servico-de-gas-sf6","status":"publish","type":"post","link":"https:\/\/gasquip.com\/pt\/when-should-you-replace-your-sf6-gas-service-hoses\/","title":{"rendered":"Quando voc\u00ea deve substituir as mangueiras de servi\u00e7o de g\u00e1s SF6?"},"content":{"rendered":"<p><strong>Resposta curta: <\/strong>pelo menos a cada 6 anos. <strong><a href=\"https:\/\/gasquip.com\/pt\/categoria-de-produto\/sf6-gas-handling\/mangueiras\/\">Clique aqui para comprar<\/a><\/strong><\/p>\n\n\n\n<p><strong>Resposta longa:<\/strong><\/p>\n\n\n\n<p>Seguindo as diretrizes estabelecidas pela DIN 20066 e ISO\/TR 17165-2, nosso objetivo \u00e9 garantir a seguran\u00e7a, o desempenho e a longevidade de seus conjuntos de mangueiras. Uma mangueira defeituosa leva a emiss\u00f5es de g\u00e1s SF6, contamina\u00e7\u00f5es por g\u00e1s, perda de efici\u00eancia e grandes preocupa\u00e7\u00f5es de seguran\u00e7a. Ao implementar as melhores pr\u00e1ticas para armazenamento e substitui\u00e7\u00e3o de mangueiras, voc\u00ea pode otimizar a efici\u00eancia e, ao mesmo tempo, minimizar os riscos. Vamos explorar mais!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Compreendendo o controle de idade e prazo de validade: <\/h2>\n\n\n\n<p>O controle da idade \u00e9 crucial para garantir que as mangueiras de servi\u00e7o de g\u00e1s SF6 sejam usadas antes que seu prazo de validade expire. O prazo de validade refere-se ao per\u00edodo durante o qual a mangueira mant\u00e9m todas as suas capacidades para o servi\u00e7o pretendido. O armazenamento adequado e o cumprimento das datas de fabrica\u00e7\u00e3o s\u00e3o fatores essenciais no controle da idade e no uso do primeiro a entrar, primeiro a sair (FIFO).<br><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Diretrizes DIN 20066 e ISO\/TR 17165-2:<\/h2>\n\n\n\n<p>Nos pa\u00edses de l\u00edngua alem\u00e3, a norma DIN 20066:2002-10, referida pelas associa\u00e7\u00f5es comerciais, fornece recomenda\u00e7\u00f5es espec\u00edficas para conjuntos de mangueiras. De acordo com <a href=\"https:\/\/www.din.de\/en\"><strong>DIN 20066<\/strong><\/a>, a mangueira de produ\u00e7\u00e3o (mangueira a granel) deve ter menos de 4 anos a partir da data de fabrica\u00e7\u00e3o. <strong>A vida \u00fatil total, incluindo armazenamento, n\u00e3o deve exceder 6 anos,<\/strong> com um per\u00edodo de armazenamento n\u00e3o superior a 2 desses 6 anos.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Inspe\u00e7\u00e3o Visual e Teste de Press\u00e3o:<\/h2>\n\n\n\n<p>Independentemente do per\u00edodo de armazenamento, \u00e9 fundamental realizar uma inspe\u00e7\u00e3o visual antes de utilizar as mangueiras armazenadas. Se surgir alguma d\u00favida em rela\u00e7\u00e3o \u00e0 funcionalidade (por exemplo, rachaduras, ferrugem ou outros danos), o teste de press\u00e3o dever\u00e1 ser realizado antes da implanta\u00e7\u00e3o. Nos casos em que persistam d\u00favidas ou haja danos significativos, recomenda-se descartar a mangueira para garantir a seguran\u00e7a.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Melhores pr\u00e1ticas para armazenamento de mangueiras:<\/h2>\n\n\n\n<p> O armazenamento adequado da mangueira \u00e9 essencial para manter a integridade e funcionalidade da mangueira. Aqui est\u00e3o algumas pr\u00e1ticas recomendadas a serem seguidas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ambiente limpo, fresco e seco: Armazene as mangueiras em uma \u00e1rea limpa, fresca e seca, de prefer\u00eancia em temperatura ambiente, para evitar degrada\u00e7\u00e3o.<\/li>\n\n\n\n<li>Prote\u00e7\u00e3o contra luz solar e umidade: Evite a exposi\u00e7\u00e3o direta \u00e0 luz solar e \u00e0 umidade, pois podem degradar o material da mangueira com o tempo.<\/li>\n\n\n\n<li>Mantenha-se afastado de equipamentos el\u00e9tricos de alta pot\u00eancia: Guarde as mangueiras longe de equipamentos el\u00e9tricos de alta pot\u00eancia para minimizar o risco de danos el\u00e9tricos.<\/li>\n\n\n\n<li>Evite produtos qu\u00edmicos corrosivos: Evite o contato entre as mangueiras e produtos qu\u00edmicos corrosivos, pois eles podem deteriorar os materiais das mangueiras.<\/li>\n\n\n\n<li>Prote\u00e7\u00e3o contra luz ultravioleta: Proteja as mangueiras da exposi\u00e7\u00e3o \u00e0 luz ultravioleta (UV), pois ela pode acelerar a degrada\u00e7\u00e3o.<\/li>\n\n\n\n<li>Prote\u00e7\u00e3o contra insetos\/roedores: Tome precau\u00e7\u00f5es para evitar infesta\u00e7\u00f5es por insetos ou roedores, que podem causar danos \u00e0s mangueiras armazenadas.<\/li>\n\n\n\n<li>Separadas de materiais radioativos: Armazene as mangueiras separadamente de materiais radioativos para evitar qualquer contamina\u00e7\u00e3o ou interfer\u00eancia potencial.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">5. Seguran\u00e7a em primeiro lugar:<\/h2>\n\n\n\n<p>Considere sempre os conjuntos de mangueiras como componentes relevantes para a seguran\u00e7a. Em caso de d\u00favida, priorize a seguran\u00e7a realizando inspe\u00e7\u00f5es minuciosas, testes de press\u00e3o ou descartando mangueiras que apresentem sinais de danos ou degrada\u00e7\u00e3o.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00c9 hora de algumas novas mangueiras SF6? <\/h2>\n\n\n\n<p> Vendemos mangueiras de borracha para manuseio de g\u00e1s SF6 diretamente em nosso site. <strong><a href=\"https:\/\/gasquip.com\/pt\/categoria-de-produto\/sf6-gas-handling\/mangueiras\/\">Clique aqui<\/a><\/strong> para conferir o que oferecemos. Tem um projeto personalizado ou deseja uma montagem, acess\u00f3rio ou material personalizado? <strong><a href=\"https:\/\/gasquip.com\/pt\/categoria-de-produto\/sf6-gas-handling\/mangueiras\/\">Entre em contato conosco.<\/a><\/strong> <\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-1024x1024.png\" alt=\"Mangueira de g\u00e1s DN20 SF6\" class=\"wp-image-5321\" width=\"236\" height=\"236\" srcset=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png 1024w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-300x300.png 300w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-150x150.png 150w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-768x768.png 768w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-600x600.png 600w, https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front-100x100.png 100w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Short answer: at least every 6 years. Click here to buy Long answer: Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of your hose assemblies. A bad hose leads to SF6 gas emissions, gas contaminations, loss of efficiency, and major safety concerns. By [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5321,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","footnotes":""},"categories":[19,79,1],"tags":[],"class_list":["post-8132","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","category-learning","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>When Should You Replace Your SF6 Gas Service Hoses?<\/title>\n<meta name=\"description\" content=\"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gasquip.com\/pt\/quando-voce-deve-substituir-suas-mangueiras-de-servico-de-gas-sf6\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"When Should You Replace Your SF6 Gas Service Hoses?\" \/>\n<meta property=\"og:description\" content=\"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gasquip.com\/pt\/quando-voce-deve-substituir-suas-mangueiras-de-servico-de-gas-sf6\/\" \/>\n<meta property=\"og:site_name\" content=\"GasQuip\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/gasquiptx\" \/>\n<meta property=\"article:published_time\" content=\"2023-05-15T20:25:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-20T13:24:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Luke Benden\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Luke Benden\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"},\"author\":{\"name\":\"Luke Benden\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\"},\"headline\":\"When Should You Replace Your SF6 Gas Service Hoses?\",\"datePublished\":\"2023-05-15T20:25:35+00:00\",\"dateModified\":\"2023-06-20T13:24:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"},\"wordCount\":495,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"articleSection\":[\"General\",\"Learning\",\"Uncategorized\"],\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\",\"name\":\"When Should You Replace Your SF6 Gas Service Hoses?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"datePublished\":\"2023-05-15T20:25:35+00:00\",\"dateModified\":\"2023-06-20T13:24:09+00:00\",\"description\":\"Adhering to guidelines set forth by DIN 20066 and ISO\\\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#primaryimage\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2021\\\/05\\\/DN20-Hose-Front.png\",\"width\":1024,\"height\":1024,\"caption\":\"DN20 SF6 Gas Hose\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/when-should-you-replace-your-sf6-gas-service-hoses\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/gasquip.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"When Should You Replace Your SF6 Gas Service Hoses?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#website\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"name\":\"GasQuip\",\"description\":\"SF6 Gas Equipment\",\"publisher\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/gasquip.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#organization\",\"name\":\"GasQuip\",\"url\":\"https:\\\/\\\/gasquip.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"contentUrl\":\"https:\\\/\\\/gasquip.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-Original-PNG-Cropped.png\",\"width\":2819,\"height\":702,\"caption\":\"GasQuip\"},\"image\":{\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/gasquiptx\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/gasquip.com\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCUCicTtyc2zeJMcj5NMA0Ww\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/gasquip.com\\\/#\\\/schema\\\/person\\\/6f7f2b2ccf37d227b39a8643b958a3cf\",\"name\":\"Luke Benden\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g\",\"caption\":\"Luke Benden\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Quando voc\u00ea deve substituir as mangueiras de servi\u00e7o de g\u00e1s SF6?","description":"Seguindo as diretrizes estabelecidas pela DIN 20066 e ISO\/TR 17165-2, pretendemos garantir a seguran\u00e7a, o desempenho e a longevidade das mangueiras.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gasquip.com\/pt\/quando-voce-deve-substituir-suas-mangueiras-de-servico-de-gas-sf6\/","og_locale":"pt_BR","og_type":"article","og_title":"When Should You Replace Your SF6 Gas Service Hoses?","og_description":"Adhering to guidelines set forth by DIN 20066 and ISO\/TR 17165-2, we aim to ensure the safety, performance, and longevity of hoses.","og_url":"https:\/\/gasquip.com\/pt\/quando-voce-deve-substituir-suas-mangueiras-de-servico-de-gas-sf6\/","og_site_name":"GasQuip","article_publisher":"https:\/\/www.facebook.com\/gasquiptx","article_published_time":"2023-05-15T20:25:35+00:00","article_modified_time":"2023-06-20T13:24:09+00:00","og_image":[{"width":1024,"height":1024,"url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","type":"image\/png"}],"author":"Luke Benden","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Luke Benden","Est. tempo de leitura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#article","isPartOf":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"},"author":{"name":"Luke Benden","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf"},"headline":"When Should You Replace Your SF6 Gas Service Hoses?","datePublished":"2023-05-15T20:25:35+00:00","dateModified":"2023-06-20T13:24:09+00:00","mainEntityOfPage":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"},"wordCount":495,"commentCount":0,"publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"image":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","articleSection":["General","Learning","Uncategorized"],"inLanguage":"pt-BR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/","url":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/","name":"Quando voc\u00ea deve substituir as mangueiras de servi\u00e7o de g\u00e1s SF6?","isPartOf":{"@id":"https:\/\/gasquip.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"image":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage"},"thumbnailUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","datePublished":"2023-05-15T20:25:35+00:00","dateModified":"2023-06-20T13:24:09+00:00","description":"Seguindo as diretrizes estabelecidas pela DIN 20066 e ISO\/TR 17165-2, pretendemos garantir a seguran\u00e7a, o desempenho e a longevidade das mangueiras.","breadcrumb":{"@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#primaryimage","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2021\/05\/DN20-Hose-Front.png","width":1024,"height":1024,"caption":"DN20 SF6 Gas Hose"},{"@type":"BreadcrumbList","@id":"https:\/\/gasquip.com\/when-should-you-replace-your-sf6-gas-service-hoses\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/gasquip.com\/"},{"@type":"ListItem","position":2,"name":"When Should You Replace Your SF6 Gas Service Hoses?"}]},{"@type":"WebSite","@id":"https:\/\/gasquip.com\/#website","url":"https:\/\/gasquip.com\/","name":"G\u00e1sQuip","description":"Equipamento de g\u00e1s SF6","publisher":{"@id":"https:\/\/gasquip.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gasquip.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/gasquip.com\/#organization","name":"G\u00e1sQuip","url":"https:\/\/gasquip.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/","url":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","contentUrl":"https:\/\/gasquip.com\/wp-content\/uploads\/2020\/10\/Logo-Original-PNG-Cropped.png","width":2819,"height":702,"caption":"GasQuip"},"image":{"@id":"https:\/\/gasquip.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/gasquiptx","https:\/\/www.linkedin.com\/company\/gasquip.com","https:\/\/www.youtube.com\/channel\/UCUCicTtyc2zeJMcj5NMA0Ww"]},{"@type":"Person","@id":"https:\/\/gasquip.com\/#\/schema\/person\/6f7f2b2ccf37d227b39a8643b958a3cf","name":"Lucas Benden","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6572a10e4f78b5b8da7eac404f75201e0eeace69be756edae016d8b45e02b445?s=96&d=mm&r=g","caption":"Luke Benden"}}]}},"_links":{"self":[{"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/posts\/8132","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/comments?post=8132"}],"version-history":[{"count":0,"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/posts\/8132\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/media\/5321"}],"wp:attachment":[{"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/media?parent=8132"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/categories?post=8132"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gasquip.com\/pt\/wp-json\/wp\/v2\/tags?post=8132"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}